Nata Scope of Accreditation

SCOPE OF ACCREDITATION -No. 16641

ACCREDITATION NO: 16641

Switchmode Power Supplies Pty Ltd

Switchmode Power Supplies
1/37 Leighton Place
HORNSBY NSW 2077


Contact: Martin Griffith
PHONE: (02) 9476 0300 FAX: (02) 9476 0479 MOBILE:
EMAIL: martin.griffith@switchmode.com.au
WEB SITE: www.switchmode.com.au

Contact: Mr Graham Gillard

Mobile: 0403 657 702
Phone: (02) 9476 0300
Fax: (02) 9476 0479

Email: graham.gillard@switchmode.com.au


FACILITIES: Public testing service


This laboratory complies with the requirements of ISO/IEC 17025 (2005)
The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise


1.39 Indicating and recording instruments 1.39 Indicating and recording instruments
.01 D.C. voltmeters
    By the methods of - WI.WC.31
    with least uncertainties of measurement of -
    0.57% from 1 mV to 10 mV
    0.058% from 10 mV to 120 mV
    0.0013% from 0.12 V to 1000 V

.02 A.C. voltmeters
    By the methods of - WI.WC.35
    from 10 mV to 120 V
    with least uncertainties of measurement of -
     0.41% from 10 Hz to 20 kHz
     0.62% from 20 kHz to 50 kHz
     1.21% from 50 kHz to 100 kHz
     from 120 V to 1000 V
     with least uncertainties of measurement of -
     0.26% from 50 kHz to 60 kHz

.03 D.C. ammeters
     By the methods of - WI.WC.33; WI.WC.34
     with least uncertainties of measurement of -
     0.092% from 100 μA to 1 mA
     0.25% from 1 mA to 10 mA
     0.093% from 10 mA to 100 mA
     0.22% from 100 mA to 1 A
     0.19% from 1 to 10 A
     0.092% from 10 to 400 A

.04 A.C. ammeters
     By the methods of - WI.WC.37; WI.WC.38
     with least uncertainties of measurement of -
     0.51% from 10 Hz to 5 kHz from 10 mA to 1 A
     0.47% from 50 Hz to 60 Hz and at 400 Hz from 1 to 20 A
     0.41% from 50 Hz to 60 Hz from 20 to 100 A

.05 Wattmeters
     DC power from 1 to 1000V and 0.1 to 400 A (limited to 50kW)
     by the methods of - WI.WC.41
    with least uncertainties of measurement of -0.62%
  


Active Power from 1 to 750 V and 0.1 to 100 A (limited to 50kW) at Unity Power-factor from 50 to 60 Hz
by the methods of - WI.WC.41
with least uncertainties of measurement of -
0.66%


3.07 Power supplies and stabilisers
      DC Voltage from 1 mV to 1000 V by the methods of - WI.WT.31  with least uncertainties of measurement of -
     0.57% from 1 mV to 10 mV
     0.058% from 10 mV to 120 mV
     0.013% from 0.12 V to 1000 V

     A.C. voltage from 10 mV to 1000 V and 10 Hz to 100 kHz
     by the methods of - WI.WT.35 from 10 mV to 120 V with least uncertainties of measurement of -
     0.41% from 10 Hz to 20 kHz
     0.62% from 20 kHz to 50 kHz
     1.21% from 50 kHz to 100 kHz
     from 120 V to 1000 V with least uncertainties of measurement of -
     0.26% from 50 Hz to 60 Hz

     D.C. current from 100 μA to 400 A
     by the methods of - WI.WT.33; WI.WT.34 with least uncertainties of measurement of -
     0.092% from 100 μA to 1 mA
     0.25% from 1 mA to 10 mA
     0.093% from 10 mA to 100 mA
     0.22% from 100 mA to 1 A
     0.19% from 1 to 10 A
     0.092% from 10 to 400 A

     A.C. current by the methods of - WI.WT.37; WI.WT.38 with least uncertainties of measurement of -
     0.51% from 10 mA to 1 A from 10 Hz to 5 kHz
     0.47% from 1 to 20 A from 50 Hz to 60 Hz and at 400 Hz
     0.41% from 20 to 100 A from 50 Hz to 60 Hz

     DC power by the methods of - WI.WT.41 from 1 to 1000 V and 0.1 to 400 A (limited to 50kW) with least uncertainties of measurement of -
     0.62%

     Active Power by the methods of - WI.WT.41
      from 1 to 750 V and 0.1 to 100 A (limited to 50kW) at Unity Power-factor from 50 to 60 Hz
      with least uncertainties of measurement of -
      0.66%

.01 Power supplies
.03 Power conditioners

3.11 Power supply equipment and systems
.01 Electric parameters
      DC Voltage from 1 mV to 1000 V  by the methods of - WI.WT.31 with least uncertainties of measurement of -
      0.57% from 1 mV to 10 mV
      0.058% from 10 mV to 120 mV
      0.013% from 0.12 V to 1000 V

      A.C. voltage from 10 mV to 100 kHz and 10 Hz to 100 Hz by the methods of - WI.WT.35 from 10 mV to 120 V
      with least uncertainties of measurement of -
      0.41% from 10 Hz to 20 kHz
      0.62% from 20 kHz to 50 kHz
      1.21% from 50 kHz to 100 kHz
      from 120 V to 1000 V with least uncertainties of measurement of -
      0.26% from 50 Hz to 60 Hz

      D.C. current from 100 μA to 400 A by the methods of - WI.WT.33; WI.WT.34
      with least uncertainties of measurement of -
      0.092% from 100 μA to 1 mA
      0.25% from 1 mA to 10 mA
      0.093% from 10 mA to 100 mA
      0.22% from 100 mA to 1 A
      0.19% from 1 to 10 A
      0.092% from 10 to 400 A

     A.C. current by the methods of - WI.WT.37; WI.WT.38 with least uncertainties of measurement of -
     0.51% from 10 mA to 1 A from 10 Hz to 5 kHz
     0.47% from 1 to 20 A from 50 Hz to 60 Hz and at 400 Hz
     0.41% from 20 to 100 A from 50 Hz to 60 Hz

     DC power by the methods of - WI.WT.41 from 1 to 1000 V and 0.1 to 400 A (limited to 50 kW)
     with least uncertainties of measurement of -
     0.62%

     Active Power by the methods of - WI.WT.41 from 1 to 750 V and 0.1 to 100 A (limited to 50 kW) at Unity Power-factor from 50 to 60 Hz
     with least uncertainties of measurement of -
     0.66%

(Last Modified: 30-NOV-16 )

Contact Switchmode

Switchmode Power Supplies Pty Ltd
U1 37 Leighton Place
Hornsby
NSW 2077


Phone: 02 9476 0300
Fax: 02 9476 0479
Email: service@switchmode.com.au